Download our slide show here: CM2800 Constant Monitor Capabilities
ESD Constant monitors reduce production costs by eliminating the time spent on testing wrist straps before each shift. Further savings may be realized by reduced ESD damage from broken wrist straps. Transforming Technologies manufactures two types of monitors:
Impedance (or single wire) constant monitors
The impedance monitor uses a detection circuit designed to reduce false alarms and eliminate adjustments. It uses the phase difference between current and voltage to detect changes in impedance of the cord, band and person. A very low AC voltage is used for constant sensing. Any standard wristband and coil cord can be used.
Resistance (or Dual Wire) constant monitors
This type of monitor is used with a two wire (dual conductor) wrist strap. When a person is wearing a wrist strap, the monitor observes the resistance of the loop, consisting of a wire, a person, a wrist-band, and a second wire. If any part of the loop should open (become disconnected or have out of limit resistance), the circuit will go into the alarm state. An important feature of the Dual Wire Wrist Strap is that even if one conductor is severed, the operator has reliable path-to-ground with other
Transforming Technologies Line of Constant Monitors.
Click here for more information.