IN1200

Ptec IN2000 Bench Top Ionizer – Removable Emitter Assembly

Buy Now

Item #: IN1200

  • Remove Static Charges Quickly and Efficiently
  • Removable Emitter Point System Makes Service and Maintenance a Breeze
  • Perfect for Single Station Table Top, Bench or Desk Use
  • Small Footprint – Does Not Take Up Space
Quantity:

Description

Benchtop Blower Ptec™ IN2000
The Ptec™ IN2000 AC benchtop air ionizer is a small, efficient static elimination device with variable fan speed for protecting electronic components and general static protection. The IN2000 emitter assembly can be quickly removed and cleaned which eliminates maintenance costs and equipment downtime and ensures your ionizer has optimal static eliminating performance.

Using AC corona technology, to make the air more conductive, Ptec™ ionizers produce a balanced stream of positive and negative air ions that never need calibration. These devices are used in many industries and manufacturing applications where static electricity is a problem.

Maintenance Friendly Ionizer

The IN2000 requires minimal service and maintenance and was designed to make it as simple as possible. The ionizer’s emitter points are enclosed in a removable assembly which can be easily removed for service. These features eliminate maintenance costs and equipment downtime and ensures your ionizer has optimal static eliminating performance.

About Ptec™ Technology

A specialized piezoelectric high voltage transformer makes Ptec™ ionizers among the most reliable ionizers manufactured. Small, lightweight and stable, Ptec™ products are designed to remain in balance and to alarm when the HV output affects performance. The model IN2000 benchtop static eliminator produces a 68KHz AC output of approximately 2200V and a continuous stream of balanced air ions. Ionizers that use Ptec™ technology do not require calibration and only minimal maintenance.

Verification and Calibration:
The IN2000 ionizer comes factory calibrated and with a calibration certificate.  Ionizer performance can be tested and verified with a charge plate monitor. Important tests to perform are positive and negative decay times and ion balance. It is recommended to test ionizer performance at least 1 per year.

Additional information

Weight 4 lbs
Dimensions 12 × 10 × 10 in
Coverage

1ft. x 5ft. area

Decay

Less Than 1secs at 12in.

Balance

0 +/-10 volts

We have resellers for this product but we have not posted website referal links at this time. You can contact us phone or by adding this item to your quote using the "Add to Quote" Button above. We will get you the information you need. Thanks!

Translate »